Command Line Interface Guide

or
omconfig mainsystem info index=0 tag=buildsys
Index 0 always defaults to the main system chassis. The following command omits index=n, but
accomplishes the same:
omconfig chassis info tag=buildsys
or
omconfig mainsystem info tag=buildsys
An acceptable command, when executed, results in the following message:
Chassis info set successfully.
For some chassis, you can assign a different name. You cannot rename the main system chassis. In the
following example, the command renames chassis 2 from storscsi1 to storscsia:
omconfig chassis info index=2 name=storscsia
or
omconfig mainsystem info index=2 name=storscsia
As with other commands, the CLI issues an error message if you do not have a chassis 2 (the main
chassis=0). The CLI allows you to issue commands only for the system configuration you have.
Omconfig Chassis Leds Or Omconfig Mainsystem Leds
Use the omconfig chassis leds or omconfig mainsystem leds command to specify when to flash a chassis
fault LED or chassis identification LED. This command also allows you to clear the LED of the system hard
drive. The following table displays the valid parameters for the command.
Table 26. Valid Parameters Of Omconfig Chassis Leds Or Omconfig Mainsystem Leds
name=value pair 1 name=value pair 2 Description
index=<n> NA Number of the chassis where the LED resides
(defaults to chassis 0, main system chassis).
led=fault severity=warning | critical Select to flash the LED either when a warning
event occurs or when a critical event occurs.
led=hdfault action=clear Sets the number of faults for the hard drive
back to zero (0).
led=identify flash=off | on time-out=<n> Sets the chassis identification LED to off or on.
Set the time-out value for the LED to flash to a
number of seconds.
Omconfig Chassis Memorymode Or Omconfig Mainsystem Memorymode
Use the omconfig chassis memorymode or omconfig mainsystem memorymode command to specify
the redundancy mode to use for the system memory in case of memory errors.
Redundant memory enables a system to switch to other available memory modules if unacceptable
errors are detected in the modules that the system is currently using. The omconfig chassis
memorymode or omconfig mainsystem memorymode command allows you to disable redundancy;
when you disable redundancy, you instruct the system not to switch to other available memory modules
when the memory module the system is using begins to encounter errors. To enable redundancy,
choose among spare, mirror, raid, and DDDC.
86