HP P9000 Command View Advanced Edition Suite Software 7.3.1-00 CLI Reference Guide

Obtain this value from the execution result of the GetStorageArray (subtarget=PortCon-
troller) command. Execute this command by specifying only the model and serialnum
parameters, and PortController for the subtarget parameter. In the execution result of
this command, the controllerID value appears under An instance of PortController.
Use this controllerID value to specify the ctrlid parameter.
controllername
Obtain this value from the execution results of the GetStorageArray (subtarget=PortCon-
troller) command. In the execution results, displayName is displayed below An instance
of PortController. Specify this value as controllername.
Command execution example
hdvmcli ModifyPortController -o "D:\logs\ModifyPortController.log"
"serialnum=10001" "model=XP1024" "ctrlid=1" "adaptermode=1"
Command execution result
RESPONSE:
An instance of StorageArray
.
. (Attributes of StorageArray are omitted here)
.
List of 1 PortController elements:
An instance of PortController
objectID=*****
cluster=1
card=1
controllerID=1
displayName=CHA-1P
mode=1
type=12
*****: The value is encoded by the CLI.
ModifyVirtualVolume
The ModifyVirtualVolume command changes the settings related to a THP/Smart volume.
For P9500
This command expands a THP/Smart volume.
This command changes the tiering policy for Smart volumes (microcode version 70-02-50-00/00
or later is required).
This command enables or disables hardware tier relocation for a Smart volume.
For XP24000/XP20000
This command assigns a THP volume to a THP pool.
This command releases a THP volume from a THP pool.
This command changes the usage threshold for THP volumes.
CLI Reference Guide 207