User`s guide

xPC Target Interface Blocks to Simulink Models
8-7
xpclib/Misc sublibrary. See “From xPC Target” on page 34-10 in the xPC
Target I/O reference documentation for further configuration details.
Note The use of From xPC Target blocks require a connection between the
host and target PC. If there is no connection between the host and target PC,
operations such as opening a model that contains these blocks or copying
these blocks within or between models, will take significantly longer than
normal.
Block Parameters
xPC Target application name — The function xpcsliface automatically
enters a name entry for this parameter. It is the same name as the Simulink
model that xPC Target uses to build the target application.
Signal name (block name) — The function xpcsliface automatically enters
a name entry for this parameter.
Observer sample time — The function xpcsliface automatically enters the
sample time for the Simulink block with this signal. It can be equal to the
model base sample time or a multiple of the base sample time.