User`s guide
get (scope object)
14-32
NumSamples
Number of contiguous samples
captured during the acquisition of a
data package. If the scope stops before
capturing this number of samples, the
scope has the collected data up to the
end of data collection, then has zeroes
for the remaining uncollected data.
Note that you should know what type of
data you are collecting, it is possible
that your data contains zeroes.
For scopes of type
'File', this
parameter works in conjunction with
the
AutoRestart check box. If the
AutoRestart box is selected, the file
scope collects data up to
Number of
Samples
, then starts over again,
overwriting the buffer. If the
AutoRestart box is not selected, the file
scope collects data only up to
Number
of Samples
, then stops.
Yes
ScopeId
A numeric index, unique for each scope.
Signals
List of signal indices from the target
object to display on the scope.
StartTime
Time within the total execution time
when a scope begins acquiring a data
package.
For scopes of type
'Target', this
parameter has no effect.
Property Description Writable