- Texas Instraments Mixed-Signal Processor Model MSP50C6xx User's Guide

Individual Instruction Descriptions
4-155Assembly Language Instructions
4.14.59 RFM Reset Fractional Mode
Syntax
[label] name Clock, clk Word, w With RPT, clk Class
RFM 1 1 N/R 9d
Execution STAT.FM 0
PC PC + 1
Flags Affected None
Opcode
Instructions 16 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0
RFM 1 1 1 1 1 1 1 1 0 1 1 0 1 0 0 0 0
Description Resets fractional mode. Clears bit 3 in status register (STAT). Disable
multiplier shift mode for unsigned fractional or integer arithmetic.
See Also SFM
Example 4.14.59.1 RFM
Resets the fractional mode. Clears FM bit of STAT.