- TMS370 Microcontroller/Gang Programmer User's Guide

Uploading a Device’s Contents Into PC Memory
3-21
unable to communicate with TMS370 device – Retry, Abort
You should inspect all of the devices for misalignment or bent pins. You may
have to remove devices until the bad device is found.
Once the actual uploading begins, it proceeds packet by packet in180-byte
segments. Before a packet is uploaded, the programmer verifies that the
source device address is inside the valid address ranges defined for the cur-
rent device type. If the address is not inside the range, the following error mes-
sage is displayed.
Address out of range, (press any key)
Press any key to erase the error message and return to the display command
menu.
During the uploading process, the programmer displays a status message on
the bottom line of the screen to indicate the address currently being read.
Reading at address 7000 (hit ESC key to abort)
This message is updated when the programmer starts to upload the next pack-
et.
If you want to terminate the uploading process before it has completed, press
to abort the process and return to the display command menu.