HP 3PAR Solaris Implementation Guide

NOTE: A 10 Gb iSCSI (only) requires a one-time configuration using the controlport command.
Use the showport and showport -i commands to verify the configuration setting. Example:
If State=config_wait or Firmware=0.0.0.0, use the controlport config iscsi
<n:s:p> command to configure. Use the showport and showport -i commands to verify the
configuration setting.
# controlport config iscsi 0:3:2
Each HP 3PAR StoreServ Storage iSCSI target port that will be connected to an iSCSI Initiator must
be set up appropriately for your configuration as described in the following steps.
1. Set up the IP and netmask address on the iSCSI target port using the HP 3PAR OS CLI
controliscsiport command. Here is an example:
# controliscsiport addr 10.1.0.110 255.0.0.0 -f 0:3:1
# controliscsiport addr 11.1.0.110 255.0.0.0 -f 1:3:1
2. To verify the iSCSI target port configuration, issue the HP 3PAR OS CLI showport -iscsi
command.
Configuring the HP 3PAR StoreServ Storage iSCSI Ports 17