HP Data Protector 6.11 script solution for Microsoft Office SharePoint Server 2007 and SharePoint Server 2010

23
Limitations
The omnir command syntax should not contain more than 8191 characters. If you have so many
tree objects that the syntax exceeds 8191 characters, split the objects and run two separate
sessions.
After the restore
After the restore:
1. Enable and start the service IIS Admin Service (only if the whole farm was restored)
2. Enable the service Office SharePoint Server Search / SharePoint Server
Search 14.
3. Bring the Microsoft SQL Server instances online (if offline).
4. Return the farm to a working state (that is, resume background activities and crawling, unlock
sites, and start the Microsoft SharePoint Server services) by running:
moss_backup.ps1 resumefarm
Restoring index files on the Query system
This section is applicable for Microsoft Office SharePoint Server 2007 only. The Office
SharePoint Server Search service is enabled on two separate Microsoft Office SharePoint
Server 2007 systems, so that one is assigned the Indexing and the other the Query role.
To copy the newly restored index files from the Indexing system to the Query system, perform
the following steps (depending on which Microsoft Office SharePoint Server 2007 and Windows
Shared Services service pack you have):
Service Pack 1
1. On the Query system, stop and disable the service Office SharePoint Server
Search.
2. Copy the index files from the Indexing to the Query system.
By default, index files are located in the C:\Program Files\Microsoft Office
Servers\12.0\Data\Office Server\Applications directory.
3. On the Query system, enable and start the service Office SharePoint Server
Search.
Service Pack 2
On the Query system, run:
stsadm o search reprovisionindex ssp SSPName
for each Shared Services Provider separately.
Troubleshooting
After restore, you cannot connect to the Central Administration web page
Problem
After restore, when you try to connect to the Microsoft SharePoint Central Administration web
page, an error similar to the following is displayed in your web browser:
Internet Explorer:
Retrieving the COM class factory for component with CLSID (BDEADEE2
C26511D0BCED-00A0C90AB50F) failed due to the following error
800703fa.
Mozilla: