HP StorageWorks 2300 Modular Smart Array reference guide (500911-001, January 2009)

88 Event code reference
96 Informational Pending configuration changes that take
effect at startup were ignored because
customer data might be present in cache.
If the requested configuration changes did
not occur, make the changes again and then
use a user-interface command to shut down
or restart the controller.
100 Informational During active-active operation, an event
(potential error) occurred while
communicating with the EMP, which reports
SES data.
101 Informational An update of EMP data has been triggered.
This event is for internal use only.
103 Informational Volume name change is complete.
104 Informational Volume size change is complete.
105 Informational Volume LUN change is complete.
106 Informational A volume has been added.
107 Critical The controller experienced the specified
critical error. In a non-redundant
configuration the controller will be restarted
automatically. In an active-active
configuration the surviving controller will kill
the controller that experienced the critical
error.
A service technician can use the debug log
to determine the problem.
108 Informational A volume has been deleted.
109 Informational The statistics for the specified vdisk have
been reset.
110 Informational Ownership of the specified vdisk has been
given to the other controller.
111 Informational The link for the specified host port is up.
112 Informational The link for the specified host port is down.
(Occurs after every LIP event.)
113 Informational The link for the specified disk channel port is
up.
114 Informational The link for the specified disk channel port is
down.
116 Critical After a recovery, the partner controller was
killed while mirroring write-back data to the
current controller. The current controller
restarted to avoid losing the data in the
partner controller's cache, but if the other
controller does not restart successfully, the
data will be lost.
To determine if data might have been lost,
check whether this event was immediately
followed by restart event 56, closely followed
by failover event 71 (specifying p1=1).
118 Informational Cache parameters have been changed for
the specified vdisk.
127 Warning The controller has detected an invalid disk
dual-port connection. This connection does
not have the benefit of fault tolerance. Failure
of the disk port would cause loss of access to
the disk.
The single disk port should be connected to
one controller only.
Table 14 Event code descriptions and recommended actions (continued)
Event
code
Event type Description Recommended action