Data migration of an existing Microsoft Windows CMS to a new Insight Software 6.3 system

SLEEP_TIME_BETWEEN_RETRIES=30000
Those configurations may increate the time to execute the export operation but will increase the success
chance to get a valid database connection.
Scenario 3: An export error for one or more plugins occurs
c:\mxexport
Warning! Export is not completely successful. Some errors are bypassed
forcibly.
The exported data file is C:/Program Files/HP/Systems Insight
Manager/data/configdata-export\Products.zip.
Solution:
Save the console output to a *.txt file and call support.
Scenario 4: The export or import includes all products, but only the HP SIM
data is required
When does this happen?
By default the data migration tool exports installed products using a set of XML configuration files. The same
applies to the import, on import both the export file and the set of installed components is examined to pull the
common set of data from the exported file.
Solution
You can import only Systems Insight Manager data, or export only HP SIM data. To do this, navigate to the
installation directory and locate the config\migration folder. Delete (or move to a new location) all
XML files
except hpsim_migrate.xml on both the source and target CMS systems.
Scenario 5: Invalid drive specification error message
Verify the following:
1. Ensure SQL service account is configured to run as a domain user or administrator user.
2. Ensure on target CMS, permissions are set on folder <HPSIM installation directory>\Systems Insight
Manager\data\configdata-import to full control for authenticated users.
Ensure all the steps are followed as specified at Step 2: Configuring remote database access for the
import operation to the target CMS.
Scenario 6: Power Management data not exported
To minimize any power consumption history loss after migration, ensure that you have completed a full
power-data collection for all systems immediately prior to the migration. Power data collection can be
initiated using the Refresh Data option on the Power/Thermal data reports page for a selected group of
systems.
If you attempt to execute the mxexport command on a system on which power management has not been
enabled or has not collected any power history data, the following warning message appears:
Warning! Plugin ipm encountered problems during export. Its data is not
exported.
Suggested action: No action required.