HP Systems Insight Manager 7.0 Installation and Configuration Guide for Microsoft Windows

This CRA task is used to fix the target CMS and is not a scheduled task. The CRA task can be
loaded after the migration completes and the HP SIM server is started. This task is disabled by
default and must be enabled and properly configured with any required credentials, then run
manually once. By default, the settings specified in the CRA Task XML are applicable to all the
discovered managed nodes. A CRA collection is also created for the CRA task to run against.
You can modify the values in the HPSIMCRATask XML files as required. The following table shows
supported settings (CRA task), default values, and allowed values. Alternatively, you can import
this task and edit these options in the task wizard.
Table 15 Editable options
Other allowed valuesDefault valueXML Property nameDefault CRA Task settings
NoYesargument_wbemCreate subscription to WBEM events
Any valid stringPublicargument_snmpreadConfigure SNMP
Set read community string:
NOTE: This will also enable the SNMP communication
between HP SIM Central Management Server (CMS)
and the SNMP agent on the managed system.
NoYesargument_snmptrapConfigure SNMP
Set traps to refer to this instance of HP Systems Insight
Manager
NOTE: A Read/Write string will be created
automatically on Windows systems.
UserHostargument_sshConfigure secure shell (SSH) access authentication
Host based authentication
NOTE: All users from this instance of HP SIM will be
authenticated on the managed system.
User based authentication for user: Each user has to
be authenticated on the managed system
EmptyCertificateargument_trustSet Trust Relationship
Trust by Certificate—Enables HP SIM users to connect
to the System Management Homepage, Onboard
Administrators, Integrated Lights-Out (version 2 and
later), and HP VCA using the HP SIM certificate for
authentication. This will deploy HP SIM certificate to
the managed system.
False—If this property is set to false,
then the user must configure
TrueusesignincredUse sign-in credentials
credentials separately. The
credentials configured using this
option are applied to all systems.
The CRA Query XML contains the full DNS names/names of all the discovered managed nodes.
You can remove, add, or modify the following tag:
<value>fulldnsname</value>
NOTE: If full DNS name is not present for a device, its system name is allowed.
To add the CRA Task and Collection, copy the HPSIMCRAQuery.xml and HPSIMCRATask.xml
files to the <HP SIM Installation>/setup directory, and enter the following command:
mxconfigrefresh
Data migration 57