Using the HP DTC Manager/UX

160
Other dtcdiag parameter definitions
13
B or b all ports on a DTC 16TN (a DTC 16TN does not have
a separate board)
0 ... 5 the boards on a DTC 48
0,1 the boards on a DTC 16
0 ... 3 for the boards or LAN board on a DTC 72MX.
The asterisk metacharacter (*) can be used to represent all non-CPU/LAN or non-
LAN boards on a DTC and it normally needs to be escaped. For example,
dtcdiag -r DTC\* \*
Additionally, a range of non-CPU/LAN or non-LAN boards can be specified by
separating the number of the boards by a hyphen (-). For example,
dtcdiag -r DTC1 0-1
ports The number of the ports on which a task is to be performed. This parameter is
optional. Port numbers are:
0 ... 7 for direct connect boards on a DTC 48 or DTC 16
0 ... 5 for modem boards on a DTC 48 or DTC 16
0 ... 23 for a 24 port MUX board on a DTC 72MX
0 ... 15 for the ports on a DTC 16TN
The asterisk metacharacter (*) can be used to represent all ports on a board of a DTC
and it normally needs to be escaped. Additionally, a range of ports can be specified
by separating the number of the ports by a hyphen (-). For example, 0-7 could be a
range.
Values returned by dtcdiag or one of its synonyms
One of the following values is returned when a dtcdiag command is executed. To
display the return value, use the HP-UX echo command after the dtcdiag command.
0 No error or no test failures.
1 Command usage incorrect.
2 Error during startup or shutdown.
3 Fatal error during execution of the command.