Troubleshooting guide

28
Software Upgrade Procedures
Step 6 Load the switch card flash memory for Slot A.
For a Release 2 switch card in Slot A, enter the following command at the System
Monitor prompt (the 0 in sd0b is a zero):
System Monitor-> fload sa (sd0b)fware/flash_sc2.rec
Reading...............(238811 bytes)
Erasing...............
Loading............................................................
............................................................
............................................................
............................................................
............................................................
............................................................
............................................................
............................................................
................................
Load Statistics
Data bytes = 84898
Overhead bytes = 42464
Messages sent = 2654
S-records = 5307
System Monitor->
For a Release 1 switch card in Slot A, enter the following command at the System
Monitor prompt (the 0 in sd0b is a zero):
System Monitor-> fload sa (sd0b)fware/flash_sc1.rec
Reading...............(162978 bytes)
Load Statistics
Data bytes = 57934
Overhead bytes = 29024
Messages sent = 1814
S-records = 3622
System Monitor->
If the Flash Load Fails
Step 7 If you do not see the System Monitor-> prompt, the flash load has failed. Do the following:
Disconnect from the NP by typing ‘. (backquote plus dot, that is, left single quote plus
period).
Reset the NP as follows (the NP in slot 1 in this example):
If you see the following error message, repeat Step 6:
flash failed to erase or is not erased
ACTION_FLASH=0x45
If you do not see this message, and you do not see the System Monitor-> prompt, go to Step 7.
If you see the following error message when loading a Release 1 switch card, reboot the primary
NP:
Flash failure occurred when setting DONE bit.. (timeout)
Then perform Step 2 to verify that the checksum is 0x5D00. This problem only occurs with
redundant Release 1 switch cards. The message is misleading, because the flash update does
complete successfully.
If you do see the System Monitor-> prompt, the flash load has completed successfully. Go to
Step 8.