Manual Chapter 5

5-31
View Data
Plotting the condition as a single point on an X-Y graph provides a true
indication of the alignment status.
The offset and angle information is intended to be used as an alignment tol-
erance only (to determine how close the alignment is based upon the last
set of alignment readings); do not use these data to align the machines. For
this reason, offset and angle are always displayed as positive numbers.
The curves at the lower left are the tolerances to shoot for. Depending on
RPM, they can be modiļ¬ed in UltraMgr and then transferred to the ana-
lyzer.
The alignment condition (with respect to the tolerances) can be monitored
by observing the tolerance target during the live move. The bullseye means
you are within the excellent tolerance range. The middle band means you
are within the acceptable range, but outside the excellent range. The out-
side band means you are within 1x - 2x of the acceptable tolerance.
The example above shows that the alignment condition is in the acceptable
range.
Tolerance
Target