Command Reference Guide

dd monthname [yy], where dd is the day and yy is the year (optional).
yymmdd, where yy is the year, mm is the month, and dd is the day.
endt <time>
Specifies that samples taken of LESB counters cease after the indicated time (<time>). Time can
be specified in hours or as a specific date. When specifying in hours, the following formats can
be used:
hh[:mm[:ss]], where hh is the hour, mm is the minute (optional), and ss is the second
(optional).
hhmm, where hh is interpreted as a 24 hour clock.
When specifying as a date, the following formats can be used:
mm/dd[/yy], where mm is the month, dd is the day, and yy is the year (optional).
monthname dd[,yy], where dd is the day and yy is the year (optional).
dd monthname [yy], where dd is the day and yy is the year (optional).
yymmdd, where yy is the year, mm is the month, and dd is the day.
SPECIFIERS
<N:S:P>
Specifies the port for which information about devices on that port are displayed. This specifier is
required for the single, both, hist, and diffhist subcommands, and optional for the
compare subcommand. If this specifier is not used with the compare subcommand, then all ports
are compared. The port is specified as follows:
node
Specifies the node.
slot
Specifies the PCI bus slot in the specified node.
port
Specifies the Fibre Channel port number of the PCI card in the specified PCI bus slot.
RESTRICTIONS
None.
EXAMPLES
The following example displays the reset of internal counters and ports:
cli% showportlesb reset
LESB reset completed
The following example displays the comparison of all ports:
cli% showportlesb compare
Port <1:0:1>
Loop <1:0:1> Time since last save: 0:00:28
ID ALPA LinkFail LossSync LossSig PrimSeq InvWord InvCRC
<1:0:1> 0xef 1 19 19 0 0 0
pd7 0x6d 1 5 0 0 270 0
pd6 0x72 1 4 0 0 524 0
pd5 0x73 1 4 0 0 335 0
showportlesb 455