OSM Service Connection User's Guide (G06.30+)

Stop ServerNet
Stops all ServerNet traffic through all or specified processors on the fabric.
IOAM (I/O Adapter Module)
Attributes
Actions
A modular I/O adapter module. There are two IOAMs in each IOAM Enclosure.
Each IOAM contains:
A ServerNet Switch Board
Two IOAM Power Supplies
Two IOAM Fans
Up to five FCSA or G4SAs
IOAMs are initially configured using the Configure Module action in the OSM Low-Level Link, as
described in the NonStop NS-Series Hardware Installation Manual (available in the Hardware
Service and Maintenance collection of NTL).
IOAM names in OSM include the group number and a module number of either 2 or 3. For example,
IOAM 13.2 is located in group 13, module 2. The other IOAM in this IOAM group is IOAM 13.3.
Note: If for any reason a ServerNet switch board is not present in a module, the fans, power
supplies, and adapters in that module will not appear in OSM.
Location in OSM Tree: System > Group > IOAM Enclosure > IOAM
Example: IOAM 13.2
Attributes
Physical
Hardware Revision
A code that identifies the generation of the component. Hardware revision
codes are used for tracking components.
Part Number
The part number of the component that was assigned in manufacturing. Use
part numbers for identifying and ordering parts.
Track ID
A unique serial number that identifies the component. Track IDs are used for
tracking components.