OSM Service Connection User's Guide (G06.30+)

Attributes
SNDA
Service State
Displayed in the Attributes tab and Attributes dialog box only if the value is
something other than OK. Values
Physical
Hardware Revision
A code that identifies the generation of the component. Hardware revision
codes are used for tracking components.
Manufacturer Identifies the manufacturer of the component.
Part Number
The part number of the component that was assigned in manufacturing. Use
part numbers for identifying and ordering parts.
Power State
Whether the component is powered on. Values
Track ID
A unique serial number that identifies the component. Track IDs are used for
tracking components.
Storage ASIC
Initialization State
The status of the storage ASIC in the CRU.
Values: Initialized, Not Initialized, Unknown
Actions
Replace
Launches the Replace SNDA guided procedure, which provides step-by-step instructions for
replacing the ServerNet/DA CRU.
Storage ASIC Initialization Test
Prompts the storage subsystem manager process ($ZZSTO) to initialize the storage ASIC in the
CRU. If initialization fails, an alarm is generated.
This action is triggered automatically when a new CRU is inserted while OSM is running or when an
SCF STATUS ADAPTER command is issued. If a CRU is inserted while OSM is not running,
perform this action after logging on to the OSM Service Connection.
Test Verify
Performs basic tests on the CRU. You can perform this action when the CRU is online.