Install Instructions

Table Of Contents
E. If this unit falls into the water, turn the main power off and then retrieve it. Do not attempt to use this filter if it has
been submerged.
F. Do not operate this unit if it has a damaged cord or plug, if it is malfunctioning or if it has been dropped or been
damaged in any manner.
G. The UV system should be installed after the POEwhole house water filtration system.
Always disconnect the water supply and completely drain the water purifier if it will be subjected to temperatures below
freezing for extended periods.
Maintenance
- For your safety, ALWAYS wear goggles and turn the power OFF before REPLACING the UV lamp or CLEANING the quartz
sleeve! Servicing the unit with the power on will also cause damage to the ballast. Never service the UV lamp or quartz
sleeve without wearing protective eyewear!
- Over time, minerals in the water slowly form a coating on the quartz sleeve. This coating must be removed periodically, as it
reduces the amount of UV light reaching the water. Please carefully clean the lamp and quartz sleeve at least 2-3 times a year
if the unit can be unmounted easily. Otherwise, please replace the lamp and quartz sleeve every 1-2 years.
- To clean the lampWear rubber, latex, or nitrile gloves to avoid contaminating the lamp.
Unplug the power, shut off both inlet and outlet valves, and remove the entire housing from the waterline. Next, drain
the water, remove the black rubber cap, which has the power cord attached, and remove the lamp from the quartz
sleeve. Wipe the lamp with a piece of lint-free cloth moistened with white vinegar.
- 10 -