- To clean the quartz sleeveUse great care when handling the quartz sleeve as it is very fragile; avoid bumping or jarring it.
Unplug the power, shut off both inlet and outlet valves, and remove the entire housing from the waterline. Next, drain
the water, remove the black rubber cap with the power cord attached, and then remove the lamp from the quartz
sleeve. Pour vinegar into the water inlet and soak the quartz sleeve until it is clear. Rinse thoroughly and carefully.
- The UVF55FS comes with a flow sensor that turns the UV unit on and off automatically with water flow. Push control switch to
button “AUTO,” and the UV lamp will start working automatically when there only water flowing. Push control switch to button
“MOVE,” the UV lamp keeps working continuously. Push the control switch button “STOP” to turn off the UV lamp. Mode AUTO
is highly recommended to protect the UV lamp.
- The amount of UV light created by the lamp decreases over time. Therefore the lamp should be replaced every 12 months.
Troubleshooting
Symptom
Solution
Leaking from the UV filter steel pipe nuts
The O-ring inside the quartz sleeve might be damaged. Please contact us
Leaking from the quartz sleeve
Replace the quartz sleeve
Leaking at the inlet/outlet
Wrap Teflon tape on the threads and reconnect the water pipe
The ballast alarm goes off; the green indicator
light is out, and the lamp doesn't power on
The lamp has exhausted its service life, replace the lamp
The lamp doesn't turn on after replacing
Check the lamp connector wires
The lamp turns on but indicator lights and
alarm are abnormal
Indicator lights are broken, replace the ballast
- 11 -