get (target object)
14-38
ExecTime
Execution time. Time, in seconds, since
your target application started running.
When the target application stops, the total
execution time is displayed.
LogMode
Controls which data points are logged:
Time-equidistant logging. Logs a data
point at every time interval. Set value to
'Normal'.
Value-equidistant logging. Logs a data
point only when an output signal from
the
OutputLog changes by a specified
value (increment). Set the value to the
difference in signal values.
Yes
MaxLogSamples
Maximum number of samples for each
logged signal within the circular buffers for
TimeLog, StateLog, OutputLog, and TETLog.
StateLog and OutputLog can have one or
more signals.
This value is calculated by dividing the
Signal Logging Buffer Size by the number
of logged signals. The
Signal Logging
Buffer Size
box is located at Simulation
menu
Configuration Parameters -> xPC
Target options
pane.
MaxTET
Maximum task execution time.
Corresponds to the slowest time (longest
time measured), in seconds, to update
model equations and post outputs.
MinTET
Minimum task execution time.
Corresponds to the fastest time (smallest
time measured), in seconds, to update
model equations and post outputs.
Property Description Writable