Installation Manual User guide

22
ATM ENVIRONMENTAL PRECAUTIONS CHECKLIST
TEMPERATURE/HUMIDITY
1. The ATM will operate over a range
of temperatures and humidity.
Generally, these parameters must
fall within the following ranges:
Temperature (Interior)
10°C - 40°C
50°F - 104° F
Relative Humidity
20% - 80%
(Non-Condensing)
Temperature (Exterior)
AC POWER REQUIREMENTS
2. Ensure the following AC power
requirements are met:
Current (Max)
5.05A @ 120V
2.01A @ 240V
Voltage
90V - 136V @ 50/60 Hz
198V - 257V @ 50/60 Hz
Power Consumption (Idle)
2.0A @ 115 VAC at 60 Hz
1.0A @ 230 VAC at 50 Hz
Isolated Ground. An equipment ground-
ing conductor that is insulated from the
conduit or raceway and all other
grounding points throughout its entire
length. The only points of electrical con-
nection will be at the duplex outlet and
service panel ends of the line.
DEDICATED TELEPHONE
3. Ensure the following telephone-
line requirements are met:
Dedicated line. The telephone line ser-
vicing the ATM will not be a “party”
line or any other shared type connec-
tion.
Proximity to Interference Sources. The
telephone line must not be in close prox-
imity to “noisy” devices that could in-
duce interference into the ATM com-
munications channel.
-35°C - 50°C
-30°F - 122°F
Relative Humidity
20% - 100%
Dedicated source. The ATM AC power
feed will be a dedicated line to which no
other electrical devices are connected.
The ATM power line will be wired for a
single “duplex”-style outlet and con-
nected directly to the AC service panel.
Power Consumption (Max Load)
606 Watts @ 120V
482 Watts @ 240V
When installing an ATM, some general environmental precautions need
to be considered. Evaluate the location where the ATM will be installed.
To help ensure proper operation of the ATM, ensure the environmental
criteria listed in this checklist are met.
RF INTERFERENCE
4. Ensure there are no devices near
the terminal that may cause RF in-
terference, such as:
TVs Coolers
Security Devices
Neon Signs
Devices with Compressors