HP Remote Graphics Software 5.4.0 User Guide

If set to 1, the logging settings in the Receiver Control Panel can be changed by the user. If set to 0, the
user will not be able to change any of the logging settings. This property can be used to permanently
enable or disable logging settings before the RGS Receiver is started. The default value is 1—logging
settings can be changed.
Rgreceiver.Log.IsFileLoggerEnabled=bool 1
Rgreceiver.Log.IsFileLoggerEnabled.IsMutable=bool 1
If set to 1, logging output from the RGS Receiver will be sent to a file. The default value is 1 —log to a
file.
Rgreceiver.Log.IsConsoleLoggerEnabled=bool 1
Rgreceiver.Log.IsConsoleLoggerEnabled.IsMutable=bool 1
This property only applies to the Linux RGS Receiver. If set to 1, logging output from the RGS Receiver
will be sent to a console window. The RGS Receiver must be started in a console window to see the
logging output. The default value is 1—log to the console.
Rgreceiver.Log.Filename=string rg.log
Rgreceiver.Log.Filename.IsMutable=bool 1
This property specifies the path to the log file, and is only used if RgReceiver.Log.IsFileLoggerEnabled is
set to 1. The default path on Windows is located in the directory where the RGS Receiver is installed,
normally C:/Program Files/Hewlett-Packard/Remote Graphics Receiver/rg.log. The default path on
Linux is $HOME/.hpremote/rgreceiver/rg.log.
Rgreceiver.Log.Level=string "INFO"
Rgreceiver.Log.Level.IsMutable=bool 1
RGS supports five logging levels: DEBUG, INFO, WARN, ERROR, and FATAL. If DEBUG is chosen, all
level of output from DEBUG to FATAL will be output to the log file. If WARN level is chosen, all levels
from WARN to FATAL will be output. The default value is INFO—all DEBUG output is turned off.
Rgreceiver.Log.MaxFileSize=int 1024
Rgreceiver.Log.MaxFileSize.IsMutable=bool 1
This sets the maximum size of the log file in kilobytes (Kbytes). The default maximum size is 1,024
Kbytes.
Rgreceiver.Log.NumBackupFiles=int 5
Rgreceiver.Log.NumBackupFiles.IsMutable=bool 1
If the log file exceeds its maximum size, the log file will be saved, and a new log file will be created.
This property sets the number of extra files that will be
saved. The default number of saved files is five.
8.5.12 Receiver image codec properties
Rgreceiver.ImageCodec.IsMutable=bool 1
If set to 1, the local user can adjust the image quality using the Remote Display Window Toolbar. If set
to 0, the user cannot change the image quality. This property and the following property can be used
to permanently set the image quality before the Receiver is started. The default value is 1—the image
quality can be adjusted by user.
ENWW
RGS Receiver properties
171