Software Instruction Manual

Toolkit utilities 42
You can add blank lines and comments to any script to make it easier to read and understand. To create
a comment, enter a semicolon, and then enter the comment text. ACU ignores all text on the same line
after a semicolon.
Sample custom input script
The sample script in this section gives all possible values for each option.
If an option is shown in bold type, you must enter a value for that option when writing your own
script.
If a value is shown in bold type, ACU uses that value as a default setting when creating new logical
drives.
You can use this script as a template for your own script. The Control category has the following options:
Action mode
Method mode
Action = Configure|Reconfigure
Method = Custom|Auto ; COMMENT: ACU cannot create a RAID 50 or RAID 60
configuration in Auto mode. You must create such configurations manually
using the Custom setting.
Controller = All | First | Slot [N][:N] | WWN [N] | SerialNumber [N] |
IOCabinet [N],IOBay [N],IOChassis [N],Slot [N],Cabinet [N],Cell [N]
ClearConfigurationWithDataLoss = Yes|No ; COMMENT: This option is now
deprecated.
LicenseKey = XXXXX-XXXXX-XXXXX-XXXXX-XXXXX
DeleteLicenseKey = XXXXX-XXXXX-XXXXX-XXXXX-XXXXX | * ; COMMENT: * is a
wild card that enables you to delete all license keys on the specified
controller.
RAIDArrayID = “XXXXXXXXXXXXXXXXXXXX”
ReadCache = 0|10|20|25|30|40|50|60|70|75|80|90|100
WriteCache = 0|10|20|25|30|40|50|60|70|75|80|90|100
RebuildPriority = Low|Medium|High
ExpandPriority = Low|Medium|High
SurfaceScanDelay = N
SSPState = Enable|Disable
PreferredPathMode = Auto|Manual
; COMMENT: the following five entries are used to optimize the
controller performance for video
MNPDelay = 0|1|2|...|60 ; units are minutes, zero indicates disabled
IRPEnable = Yes|No
DPOEnable = Yes|No
ElevatorSortEnable = Yes|No
QueueDepth = 2|4|8|16|32|Auto