Enabling and disabling Power over Ethernet
Enabling and disabling Power over Ethernet
To enable a port to receive inline power for power consuming devices, enter commands such as the
following.
Brocade#configure terminal
Brocade(config)# interface ethernet 1/1
Brocade(config-if-e1000-1/1)# inline power
After entering the above commands, the console displays the following message.
Brocade(config-if-e1000-1/1)#PoE Info: Power enabled on port 1/1.
Syntax: [no] inline power
Use the no form of the command to disable the port from receiving inline power.
NOTE
Inline power should not be configured between two switches as it may cause unexpected behavior.
NOTE
FastIron PoE and PoE+ devices can automatically detect whether or not a power consuming device
is 802.3af- or 802.3at-compliant.
Disabling support for PoE legacy power-consuming devices
Brocade PoE devices automatically support most legacy power consuming devices (devices not
compliant with 802.3af 802.3at), as well as all 802.3af- and 802.3at-compliant devices. If
desired, you can disable and re-enable support for legacy PoE power consuming devices on a
global basis (on the entire device) or on individual slots (chassis devices only). When you disable
legacy support, 802.3af- and 802.3at-compliant devices are not affected.
To disable support for legacy power consuming devices on a non-stackable device, enter the
following command at the global CONFIG level of the CLI.
Brocade(config)# no legacy-inline-power
To disable support for legacy power consuming devices on a stackable device, enter the following
command at the stack unit CONFIG level of the CLI.
Brocade(config-unit-2)# no legacy-inline-power
On chassis devices, you can disable support for legacy power consuming devices per slot. To
disable legacy support on all ports in slot 2, enter the following command at the global CONFIG
level of the CLI.
Brocade(config)# no legacy-inline-power 2
NOTE
The no legacy-inline-power command does not require a software reload if it is entered prior to
connecting the PDs. If the command is entered after the PDs are connected, the configuration must
be saved (write memory) and the software reloaded after the change is placed into effect.
Syntax: [no] legacy-inline-power [<slotnum>]