Manual Chapter 1

3-23
Options Key
Use the Up/Down Arrow to highlight a parameter in order to enter a value.
For dimension “U”, measure the diameter of the coupling (the diameter
that would be swept by the face reading) and enter the corresponding
value. For dimension “V”, measure from the center of the inboard foot of
the left machine to the point at which the rim sensor (dial indicator) would
take readings as shown in the figure above. This is usually the center (or
close to the center) of the coupling. For both measurements, measure to the
nearest 1/8” (3mm).
After both values are entered, press the Enter key to proceed to the Sensor
Measurement Location screen.
Use the Up/Down Arrow or any alphanumeric key to select which side of
the coupling the sensor is located. Actual face/rim measurements are to be
taken on the coupling half pointed to by the arrow. The sensor measure-
ment location determines the direction (sign) of the “rim” total indicator
runout (TIR).
Press the Enter key again to view the Sensor Targets screen.
18