Command Line Interface Guide

128 omconfig: Managing Components Using the Instrumentation Service
unit=watt | btuphr |
percent
watt: Configure the unit in Watts.
btuphr: Configure the unit in
BTU/hr.
percent: Configure the unit in
percentage.
config=profile
NOTE: This option is
supported on systems
prior to PowerEdge
yx2x systems.
profile=
maxperformance| apc
| osctrl | custom
maxperformance: Sets the processor
to the highest supported processor
state. It offers maximum
performance mode with minimal
power economy.
apc: Active Power Control (apc)
enables the demand-based power
management controlled by BIOS.
osctrl: OS Control (osctrl) enables
the demand-based power
management controlled by the
operating system.
custom: This profile allows you to
configure individual BIOS settings. It
offers added control by displaying the
underlying BIOS settings.
cpupowermode=min |
max | systemdbpm |
osdbpm
min: Sets the CPU power
consumption to minimum.
max: Sets the CPU power
consumption to maximum.
systemdbpm: Sets the mode to
system demand based power
management.
osdbpm: Sets the mode to operating
system demand based power
management.
NOTE: These options are applicable
only when a custom profile is selected.
Table 4-10. omconfig chassis pwrmanagement or omconfig mainsystem
pwrmanagement
(continued)
name=value pair 1 name=value pair 2 Description