OSM Service Connection User's Guide (G06.30+)

A processor and memory board (PMB), which contains a processor
A power supply (S7000 only)
A service processor (SP)
Three SCSI controllers
And for PMFs in Group 1 only, an MIOE (Ethernet controller) to provide connectivity
between the service processor and the dedicated service LAN (for OSM).
Location in OSM Tree: System > Group > Module > PMF
Slot Location: PMF CRUs are located in slots 50 and 55 of a processor enclosure (service side).
Example: PMF (1.1.55)
Attributes
PMF
Service State
Displayed in the Attributes tab and Attributes dialog box only if the value is
something other than OK. Values
Physical
Hardware Revision
A code that identifies the generation of the component. Hardware revision
codes are used for tracking components.
Manufacturer Identifies the manufacturer of the component.
Part Number
The part number of the component that was assigned in manufacturing. Use
part numbers for identifying and ordering parts.
Power State
Whether the component is powered on. Values
Track ID
A unique serial number that identifies the component. Track IDs are used for
tracking components.
Logical
Fan Voltage The current voltage of the Fan CRU.
Main Rail Voltage
The voltage of the Main Rail, which supplies power to the CRU from its
own power supply
Disabled ServerNet Ports
This attribute indicates which, if any, ServerNet router ports on this CRU
are disabled. OSM actions to disable or enable a ServerNet port are
performed as directed by OSM alarm repair actions.
SCSI-Y Voltage
The voltage of the SCSI-Y path, the path configured for mirrored disks on
a system.