HP XP7 Continuous Access Synchronous for Mainframe Systems User Guide (TK911-96003)

SSB2 error codes when SSB1 = 2E31/B901/B90A/B90B/B912/D004
DescriptionError code
(SSB2)
The pair cannot be split because of one of the following conditions:47A3
Write access permitted in the S-VOL is unsupported.
The Swap Suspend is unsupported.
The pair cannot be created because the specified P-VOL is one of the following:47BA
Used as an BC Z S-VOL.
Intervention-required or protected.
The pair cannot be created because Cnt Ac-S Z asynchronous is not supported.4A5C
The pair cannot be created because the specified P-VOL belongs to a different CLPR than the registered
consistency group CLPR.
4A96
A pair cannot be resynchronized because the specified consistency group does not have the Open/MF
attribute.
4B02
The pair cannot be created because the specified P-VOL is defined as the command device.4B04
The pair cannot be resynchronized because the specified volume is in failover in PPRC.4B22
The pair cannot be split because the specified volume is in failover in PPRC.4B23
The pair operation was rejected because the online microcode is being replaced.4B2F
The pair cannot be created because the specified P-VOL is one of the following:4B32
Used by Compatible FlashCopy
Used by Compatible FlashCopy SE
A TSE volume
The consistency group Paircreate or Pairresync was rejected because the specified P-VOL is a Compatible
FlashCopy S-VOL.
4B85
The Paircreate or Pairresync (managed by cylinder) was rejected because the specified P-VOL is fa Compatible
FlashCopy S-VOL.
4B86
The Paircreate (Time Stamp mode) was rejected because the specified volume is already used in Compatible
XRC.
4BB2
The pair operation was rejected because the necessary shared memory is not mounted in the primary system.4BE0
The command cannot be executed because the user authentication is not performed.9100
The pair cannot be created because the system identifier is not correct (left-most number in the 6-digit serial
number).
B920
You cannot run the following operations to a pair in a 2DC configuration:B927
Swap Suspend
Takeover
The pair cannot be created because the Mirror ID is invalid.B928
The pair operation was rejected because the online microcode is being replaced.B929
The pair cannot be created because the specified volume is a command device.B92A
The pair cannot be created because Cnt Ac-S Z is not installed.B934
S-VOL hide mode is not supported.B935
The specified volume is a P-VOL. The pair cannot be released because the P-VOL is specified as an S-VOL.B93B
Troubleshooting using RAID Manager 105