HP XP7 Continuous Access Synchronous for Mainframe Systems User Guide (TK911-96003)

DescriptionError code
(SSB2)
The command was rejected because the specified volume is an S-VOL. If the error occurs when the volume
is unpaired, select the volume in Remote Web Console, release the pair using the Force Delete Pairs window,
and then run the command again.
C212
The command was rejected because the secondary system is not registered, or the registered information
is invalid.
C214
The command was rejected because an internal logical error has occurred.C215
The command was rejected because the pair status is invalid.C218
The command was rejected because the P-VOL status is other than Suspended (by user) Suspended (because
of failure).
C21A
The command was rejected because the secondary system is not registered, or the registered information
is invalid.
C21C
The command was rejected because the pair release was run on a volume other than P-VOL.C22A
The command was rejected because the volume is unpaired.C22C
The command was rejected because the specified volume is the volume other than the P-VOL.C22D
The command was rejected because the pairsplit command specifying -P option (write protection of P-VOL)
was issued to a volume whose status is not Duplex.
C22E
The command was rejected because the S-VOL status is unpaired.C233
The command was rejected because an internal logical error has occurred.C234/C235/C236/C237
The command was rejected because the specified volume is the volume other than the P-VOL.C238
The command was rejected because the pair resync was operated on a volume whose status is other than
Suspended (by user) Suspended (because of failure).
C239
The command was rejected because an internal logical error has occurred.C23A
The command was rejected because the volume is unpaired.C23B
The command was rejected because the volume status is other than Duplex or Pending.C23C
The command was rejected because the command for Cnt Ac-S Z asynchronous was issued to the Cnt Ac-S
Z asynchronous volume.
C23D
The command was rejected because the volume status is COPY.C23E
The pair cannot be created because the command was issued to the command device.C267
The command was rejected because the specified consistency group number is invalid.C271
The command was rejected because the takeover command was issued to a volume whose status is not
SSWS.
C28B
The command was rejected because the secondary system is not registered, or the registered information
is invalid.
C28C
There is no volume to which the takeover command can run.C28D
The command was rejected because an internal logical error has occurred.C28E
The command was rejected because the specified volume is used as an S-VOL.C297
The pair cannot be created because the capacity that is used by software products other than Cnt Ac-S Z
exceeds license capacity.
C2A0
The command was rejected because an internal logical error has occurred.C2A1
The pair cannot be created because the used capacity exceeds the license capacity.C2A3
The command was rejected because THP V-VOL capacity is changing.C2B3
Troubleshooting using RAID Manager 107