HP XP7 Continuous Access Synchronous for Mainframe Systems User Guide (TK911-96003)

DescriptionError code
(SSB2)
The command was rejected because an internal logical error has occurred.C2B4
The pair cannot be created because the Cnt Ac-S Z P-VOL is being initialized by Business Copy.C2B5
The command was rejected because the releasing pages in THP V-VOL is in progress.C2B6
The Cnt Ac-S Z pair associated with a Cnt Ac-J Z pair cannot be added because the Cont Access Journal
3DC & 4x4 Open MF program product is not installed on the primary system.
C300
The Cnt Ac-S Z pair associated with a Cnt Ac-J Z pair cannot be added because the Cont Access Journal
3DC & 4x4 Open MF program product is not installed on the secondary system.
C301
The pair cannot be created because the S-VOL is a THP V-VOL.C304
The pair cannot be created because the capacity that is used by Cnt Ac-S Z in the secondary system exceeds
license capacity. Check license capacity, including for related software products.
C305
The volume in the secondary system or another volume that belongs to the same group is changing to Simplex
or Suspend status. Retry the operation after several minutes.
C30D
The NVS is not ON in the MCU.C310
The storage system level cache is not valid in the MCU.C311
The P-VOL is not in unpaired status.C312
The P-VOL is not in Suspended or Suspended status.C313
The P-VOL is not in unpaired status.C314
The P-VOL includes PIN data.C315
The P-VOL is in the process of drive copy for failure assistance.C316
The P-VOL is in the process of drive copy for an SVP request.C317
The P-VOL is terminating the copy task.C318
The P-VOL is in the process of collection copy.C319
The P-VOL is in the process of collection access.C31A
The P-VOL is blocked.C31B
The P-VOL is blocked and impossible to access.C31C
The P-VOL is being formatted.C31D
The P-VOL is read only.C31E
The number of remote paths is 0 (not specified).C320
The number of remote paths is smaller than the minimum required.C321
The DKC type of the primary system does not support Cnt Ac-S Z.C322
The secondary system’s sequence number, SSID, or CU are invalid.C324
The NVS is not ON in the RCU.C325
The storage system level cache is not valid in the RCU.C326
The pair cannot be created because the P-VOL is not available for remote copy.C327
The track formats of the P-VOL and the S-VOL do not match.C328
The S-VOL is protected by the Volume Retention.C32A
The P-VOL is protected by the Volume Retention.C32B
The S-VOL is protected by the Volume Retention.C32C
108 Troubleshooting