DescriptionStatusParameter name
End time of performance monitoring
If you specify this parameter, you must also specify
migrationinterval=24.
Specify a time in the range from 00:00 to 23:59 in HH:MM
format.
If this parameter is omitted, 23:59 is set.
Optional
(P9500)
monitorendtime
#3
Performance monitoring mode.
If you specify this parameter, you must also specify
tiercontrol=enable.
Specifiable values vary, depending on the microcode
version.
If the microcode version is earlier than 70-02-XX-XX/XX:
0: Periodic
If this parameter is omitted, 0 is set.
If the microcode version is 70-02-XX-XX/XX or later:
0: Periodic
1: Continuous
If this parameter is omitted, 1 is set.
Optional
(P9500)
monitoringmode
#1
If you specify threshold values for overprovisioningwarning and overprovisioninglim-
it, two warning levels related to the over-provisioning percent can be issued. For
XP24000/XP20000, these threshold values are specific to and managed by the Device Manager
server.
#2
The over-provisioning percent is the percentage of the total size of all THP volumes with respect
to the THP pool size. For example, if the pool size for Thin Provisioning Software is 500 GB and
the total size of all volumes for Thin Provisioning Software is 400 GB, the threshold value will be
80 %.
#3
There must be an interval of at least one hour between the times specified for monitorstarttime
and monitorendtime. The same time cannot be specified for monitorstarttime and
monitorendtime.
Parameter values to obtain in advance
serialnum and model
Obtain these values from the execution result of the GetStorageArray command. In the execution
result, use the arrayType value or the displayArrayType value to specify the model para-
meter, and use the serialNumber value to specify the serialnum parameter.
devnums
Obtain this value from the execution result of the GetStorageArray (subtarget=Logic-
alUnit, lusubinfo=LDEV) command. Execute this command by specifying only the model
and serialnum parameters, LogicalUnit for the subtarget parameter, and LDEV for the
lusubinfo parameter. In the execution result of this command, the devNum value of Logic-
alUnit appears under An instance of LogicalUnit. Use the devNum value of a logical
Command reference72