X25AM Programming Manual

Errors and Error Recovery for ITI and PTP
X25AM Programming Manual527201-001
5-6
Suggested Recovery Action
164 X X A disconnect was received, or the data line is occupied
(busy).
171 X X No response was received on bid/poll/select, or the
reply is invalid.
179 X X The application buffer is incorrect; a control request is
pending; or an autopoll is active.
190 X X A device error occurred; this is a hardware problem.
200 X X The device is owned by an alternate port.
201 X X The current path to the device is down; an attempt was
made to write to a non-existent process; the message-
system request was incorrectly formatted; or an error
was found in the message-system interface.
214 X X Channel timeout (path error).
218 X X An interrupt timeout occurred on a channel; or on a
controller, modem, or the line inbetween; or the modem
clock was lost (path error).
230 X X The CPU power failed, then was restored.
231 X X The controller power failed, then was restored.
Table 5-3. Errors Not Requiring Application-Dependent Recovery (page 2 of 2)
Error
Returned
by ITI
Returned
by PTP Description