Algorithm Manual Revision 4

Reverb8
36 System 6000 MKII Algorithms – Firmware version 6.5.0
Working with multiple
Reverb 8 instances
With more than one Engine running Reverb 8,
it may be useful to access more instances at a
time. Besides from opening multiple Icons, re-
member there is the “E1-4” page – see Fig10.
Fig10. Two instances of Reverb8
shown on the E1-4 page.
Reverb8 algorithm – Main page
Fig11. Reverb 8 algorithm – Main page
Name
Use the Name field to edit the name of the cur-
rently selected Preset.
Levels section
In Level
Range: Off, -115,5 to 0dB
Use the In Level parameter to set the input level
for the algorithm.
Dry Level
Range: Off, -115,5 to 0dB
Use the Dry Level parameter to set the level
of the dry, unprocessed signal that should be
passed to the output channels.
Power Correct
Range: Off, 50% and 100%
As Reverb Decay times gets longer, the Power
Correct feature can be used to lower the gain,
thereby keeping the power of the Reverb con-
stant. This feature is typically a big help when
mixing because trimming of Decay is more for-
giving (as the dry/wet balance doesn’t change).
Out Level Group 1 & Out Level Group 2
Range: Off, -115,5 to 0dB
Use the Out Level Group 1 and Out Level Group
2 parameters to set the output levels of the re-
verb channels assigned to Group 1 and Group 2.
You assign Reverb Channels to the two Groups
on the Setup page.