Personal Computer User Manual

Default Settings
http://www.motorola.com/computer/literature 3-9
3
Note: The bug does not automatically acquire all of the memory it is
allowed. It accumulates memory as necessary in one megabyte
blocks.
Field Service Menu Enable [Y/N] = N?
Remote Start Method Switch [G/M/B/N] = B?
The Remote Start Method Switch is used when the MVME5100 is cross-
loaded from another VME-based CPU in order to start execution of the
cross-loaded program.
Probe System for Supported I/O Controllers [Y/N] = Y?
Y Display the field service menu.
N Do not display the field service menu. (Default)
G Use the Global Control and Status Register to pass
and start execution of the cross-loaded program.
M Use the Multiprocessor Control Register (MPCR) in
shared RAM to pass and start execution of the cross-
loaded program.
B Use both the GCSR and the MPCR methods to pass
and start execution of the cross-loaded program.
(Default)
N Do not use any Remote Start Method.
Y Accesses will be made to the appropriate system
buses (for example, VMEbus, local MPU bus) to
determine the presence of supported controllers.
(Default)
N Accesses will not be made to the VMEbus to
determine the presence of supported controllers.