Installation and Programming Guide

30
Options
The Option function allows you to make modications to the controllers operation.
Allows program 1–8 to utilize Station 1 as a secondary Master Valve.
Allows sensor feedback to activate Program 1.
Allows you to activate or deactivate the Master Valve during station delays.
Options 1–8
Select Program to use Station 1 as a secondary Master Valve.
Activate Option 1–8 to Activate Secondary Master Valve (Station 1)
Step 1 – Turn the Function dial to the Options position.
Step 2 – Use the and buttons to select the program to modify. Use the and buttons to set the Master
Valve to Master or Station 1.
Example: Set Program 2 to use Station 1 as a secondary master valve. Press the or button until
Option# 2 is displayed. Press the or button to toggle the Master Valve option to STN 1.
Step 3 – Repeat Step 2 to modify additional programs.
Step 4 – Return the Function dial to the Auto Run position to exit Options.