HP StorageWorks HSG60 and HSG80 Array Controller and Array Controller Software Maintenance and Service Guide (EK-G80MS-SA. C01, March 2005)

Replacing BA370, M2100 & M2200 Enclosure Elements
141HP StorageWorks HSG60 and HSG80 Array Controller and Array Controller Software
Maintenance and Service Guide
Note: A countdown timer allows you a total of 2 minutes to remove the cache module.
After 2 minutes, “this controller” exits
FRUTIL,
restarts the "other controller, and
resumes operations. If this happens, perform the following steps:
a. Connect the PC or terminal to the "other controller."
b. Shut down the "other controller" by issuing the command:
SHUTDOWN THIS_CONTROLLER
c. Disconnect the PC or terminal, and reconnect it to the operational controller.
d. Return to substep 2d on page 140, and proceed.
3. For the cache module to be replaced, complete one of the following two
options after the
Remove the slot x cache module within 2
minutes
message is displayed:
For Model 2100 and 2200 enclosures:
a. Disengage both retaining levers.
b. Remove the “other controller” cache module.
For all other supported enclosures:
a. Disengage both retaining levers and partially remove the “other
controller” cache module—about halfway.
Caution: You must disable the ECB before disconnecting the ECB Y-cable
from the cache module. (If the ECB status light is off, this indicates that the
ECB is disabled.) Failure to disable the ECB can result in cache module
damage.
b. Disable the ECB by pressing the battery disable switch until the
status light stops flashing. This process takes approximately
5 seconds.
c. Disconnect the ECB Y-cable from the “other controller” cache
module.
d. Remove the cache module from the enclosure.