Instruction manual

8. USAGE EXAMPLE
IMR01Y06-E6
85
8.4 Device Assignments Example
According to the contents set by 8.3 Use Instruments Setting (P. 83), each device is assigned.
Assignment conditions
Station number of COM-JC: 1
Number of occupied station/extended cyclic: 1 station occupied 1 time (2 controllers assignment)
Automatic refresh device setting
Remote input (RX) refresh device: X1000
Remote output (RY) refresh device: Y1000
Remote register (RWr) refresh device: W0
Remote register (RWw) refresh device: W100
Special relay (SB) refresh device: SB0
Special register (SW) refresh device: SW0
Remote input (RX) and Remote output (RY)
X100F to X1000 RX0F to RX00
X101F to X1010 RX1F to RX10
Y100F to Y1000 RY0F to RY00
Y101F to Y1010 RY1F to RY10
z Device assignment table of Remote input (RX)
CPU
device number
Communication item
Remote input (RX)
address
X1000 Device address 1
(Controller 1)
Event 1 state RX00
X1001 Event 2 state RX01
X1002 Burnout state RX02
X1003 Heater break alarm (HBA) state RX03
X1004 PID/AT transfer RX04
X1005 Device address 2
(Controller 2)
Event 1 state RX05
X1006 Event 2 state RX06
X1007 Burnout state RX07
X1008 Heater break alarm (HBA) state RX08
X1009 PID/AT transfer RX09
X100A Unused RX0A
X100B Unused RX0B
Continued on the next page.
CPU of PLC
COM-JC (Station number 1)
1 station occupied 1 time
: The device that a COM-JC actually uses