AC-F/G4x Series Installation and Programming Manual 47
from Normal mode (during office hours) to Secure mode (after
office hours).
5.9.5 Auxiliary Mode 4
Auxiliary input function: Toggles Normal/Secure modes
Auxiliary output activated by: direct shunt (explanation below)
For example, in Auxiliary Mode 4, the controller is capable of
bypassing an alarm zone by shunting an alarm system’s door
sensor. The auxiliary output is to be wired in parallel to the door
sensor output. When in use, the auxiliary output is normally
open and the door sensor functions normally. When a valid code
is entered, the auxiliary relay shunts the door sensor for the
duration of the Shunt time, as defined by the auxiliary setting. If
the door is left open longer than the Shunt time, an alarm is
triggered.
5.9.6 Auxiliary Mode 5
Auxiliary input function: Door Monitor
Auxiliary output activated by: Shunt (explanation below)
For example, in Auxiliary Mode 5, the controller is capable of
shunting an alarm system. In this mode, the auxiliary input is to
be wired to the magnetic contact switch on the door. The
auxiliary relay is wired to the alarm system. Without a valid code
entered, the auxiliary relay matches the condition of the
magnetic contact switch; if the door opens, the auxiliary relay