Installation Manual

ProVision 3 Installation Manual
8100-35521-00
Rev. A1
Leidos Security Detection & Automation, Inc. Proprietary Page 64 of 119
© 2020 Leidos. All rights reserved
24. In the left hand column, click Software tests and verify that all tests pass. Correct any failures as
needed.
25. In the left hand column, under Hardware tests, click Mast antenna ISU0 test. Verify all pass.
Correct any failures as needed.
26. Click the next test under Hardware tests, Mast antenna ISU1 test, as shown in the following figure.
Verify all pass. Correct any failures as needed.
27. Restore the motor brake release jumper.
28. Move masts to the calibration position.
29. Disconnect the Ethernet cable.
30. Power the scanner off and disconnect the power cord.
31. Remove the floor center panel and retain hardware for use later.
11.21 Housing Brace Brackets
1. Install one of the two housing brace brackets (3810-10092-00) in the center hole of one of the two top
outer window angle brackets, as shown in the following figure. Notice that the outer window is
tabbed or notched where the bracket is to be placed. The housing brace bracket is fastened with one
M6 x 12mm FHC bolt (0201-10069-12).
2. Install one U-style clip (410-23861) per bracket as shown in the following figure.
Figure 68: Housing Brace Brackets
3. Repeat for other side.
11.22 Cabling Routes
1. If both the OCP and power input box are being located on the right column at the electrical enclosure
end, route all cabling along the top of the upper frame, over the top of the column and down the right
side of the electrical enclosure end (as shown at lower left of the following figure).