The active inputs and units display at the bottom of the screen. Disabled inputs are
grayed out.
7.3.2 Set up a sensor
When you use a triax, the inputs must match the triax directions, such as input A = Z, input
B = X, and input C = Y.
Procedure
1.
Activate a job.
2. From the Transient main menu, press ALT > F3 Sensor Setup or press F1 Setup / Acquire
Data > F12 Input Setup > F7 Sensor Setup.
3. Set the following options as necessary for each input.
Option Description
Change Sensor Type Select the type of sensor to use for the input.
Change Sensitivity Enter the sensitivity in volts per engineering unit, such as g's for an
accelerometer.
Change Sensor
Power
Select ON to use the accelerometer input where the analyzer powers
the sensor. Select OFF to use the volts input. No power is provided to
the sensor.
Change Signal
Coupling
The coupling mode for sensor power ON is always AC coupled. When
sensor power is OFF, the mode can be changed to AC or DC.
Change Accel Config Set the accelerometer sensors as single axis (one signal), biaxial (two
signals), or triaxial (three signals).
4. Press Enter.
7.3.3 Set data units
Set the data units for each selected input.
Procedure
1.
Activate a job.
2. From the Transient main menu, press F1 Setup / Acquire Data > F12 Input Setup.
3. For each input, select the units.
4. Press Enter.