User's Manual

Table Of Contents
If you use more than one sensor and do not use the CSI 2140 Four-Channel Input
Adapter, ensure you connected the proper cables before collecting data. Collect the
measurement for the appropriate input.
Procedure
1.
From the Balance main menu, press F4 Acquire Data > Acquire Trial Run Data for the
appropriate trial run.
If you set up multiple weight planes, additional trial runs appear on the Acquire Data
screen.
2. Add or remove the trial weight from the weight plane.
3. For each plane and location in the trial run, enter the trial weight location and
amount on the Enter Trial Weights screen, and press Enter.
If you set up multiple weight planes, press F1 Select Weight Plane 3,4 and enter the trial
weights and locations.
Tip
After you select the weight plane or location, use the up, down, left, or right arrow keys to
scroll through the fields and planes in the table.
Enter Trial Weights screenFigure 9-4:
4. If you set up multiple speeds, select the appropriate speed.
5.
Place the sensor at the measurement point location.
6. Use the up and down arrow keys to select the measurement point.
7. Ensure the machine is running.
8. Press Start Data Acq to collect data.
Balance
216
DRAFT