User Guide

Table Of Contents
www.ti.com
ReservedRIO_FLOW_CNTL0
31
R, all zeros
tt
17
R/W, 0b01
Flow_Cntl_ID0
15
R/W, 0x0000
ReservedRIO_FLOW_CNTL1
31
R, all zeros
tt
17
R/W, 0b01
Flow_Cntl_ID1
15
R/W, 0x0000
ReservedRIO_FLOW_CNTL2
31
R, all zeros
tt
17
R/W, 0b01
Flow_Cntl_ID2
15
R/W, 0x0000
ReservedRIO_FLOW_CNTL15
31
R, all zeros
tt
17
R/W, 0b01
Flow_Cntl_ID15
15
R/W, 0x0000
SRIO Functional Description
Figure 27. Flow Control Table Entry Registers (Address Offset 0x0900 - 0x093C)
Table 22. Flow Control Table Entry Registers (Address Offset 0x0900 - 0x093C)
Name Bit Access Reset Value Description
tt [17:16] R/W 01b Selects Flow_Cntl_ID length.
00b 8b IDs
01b 16b IDs
10b 11b - reserved
Flow_Cntl_ID0 [15:0] R/W 0x0000 DestID of Flow 0
Flow_Cntl_ID1 [15:0] R/W 0x0000 DestID of Flow 1
Flow_Cntl_ID2 [15:0] R/W 0x0000 DestID of Flow 2
Flow_Cntl_ID3 [15:0] R/W 0x0000 DestID of Flow 3
Flow_Cntl_ID4 [15:0] R/W 0x0000 DestID of Flow 4
Flow_Cntl_ID5 [15:0] R/W 0x0000 DestID of Flow 5
Flow_Cntl_ID6 [15:0] R/W 0x0000 DestID of Flow 6
Flow_Cntl_ID7 [15:0] R/W 0x0000 DestID of Flow 7
Flow_Cntl_ID8 [15:0] R/W 0x0000 DestID of Flow 8
Flow_Cntl_ID9 [15:0] R/W 0x0000 DestID of Flow 9
Flow_Cntl_ID10 [15:0] R/W 0x0000 DestID of Flow 10
Flow_Cntl_ID11 [15:0] R/W 0x0000 DestID of Flow 11
Flow_Cntl_ID12 [15:0] R/W 0x0000 DestID of Flow 12
Flow_Cntl_ID13 [15:0] R/W 0x0000 DestID of Flow 13
Flow_Cntl_ID14 [15:0] R/W 0x0000 DestID of Flow 14
Flow_Cntl_ID15 [15:0] R/W 0x0000 DestID of Flow 15, if all 0s this table entry represents all flows other than
flows 0 - 14
Each transmit source, including LSU or Tx CPPI queues, indicates which of the 16 flows it uses by having
a mask register. Figure 28 illustrates the required 16-bit registers with bit masks. The CPU must configure
these registers upon reset. The default setting is all 1s, indicating that the transmit source supports all
flows. If the register is set to all 0s, the transmit source communicates that it does not support any flow,
and consequently, that source is never flow-controlled. If any of the table entry counters that a transmit
source supports have a corresponding non-zero Xoff count, the transmit source is flow-controlled. A
simple 16-bit bus indicates the Xoff state of all 16 flows and is compared to the transmit source mask
register. Each source interprets this result and performs flow control accordingly. For example, an LSU
module that is flow-controlled can reload its registers and attempt to send a packet to another flow, while a
TX CPPI queue that is flow-controlled may create HOL blocking issues on that queue.
SPRU976 March 2006 Serial RapidIO (SRIO) 61
Submit Documentation Feedback